7.1 Overview

Chapter 7 describes the compliance requirements for photovoltaic (PV) systems, battery storage systems, and solar and battery ready for newly constructed single-family residential buildings. The prescriptive PV requirement sets the standard design budget for the performance compliance method. Installation of battery storage system is a compliance option, and this chapter describes the qualification requirement for this credit. The requirements for solar ready buildings are mandatory measures for newly constructed single-family residential buildings that do not have a PV system due to an exception in Section 150.1(c)14. The solar ready requirement is implemented when designing the building’s rooftop and associated equipment. The intent is to reserve a penetration-free and shade-free portion of the roof for the potential future installation of a solar energy system. There are no requirements to install panels, conduit, piping, or mounting hardware.

For information about solar water heating system, please see Chapter 5.

7.1.1 What’s new for 2022
7.1.1.1 Mandatory Measures
  1. Energy Storage System (ESS) ready is now required for all single-family buildings with one or two dwelling units. See Section 7.8 for details.
7.1.1.2 Prescriptive & Performance Compliance
  1. Revised exceptions to the PV requirement for buildings with limited Solar Access Roof Area (SARA), enforcement-authority-approved roof designs in areas with high snow loads, designs approved by the local planning department prior to January 1, 2020 with mandatory conditions for approval, and some buildings with battery storage.
  2. An additional control strategy was added to Joint Appendix JA12 for Separate Battery Storage Systems when battery systems are installed separate from on-site PV systems.

This panel displays referenced content when certain links are clicked.

This website and the messages contained in its webpages are funded by customers unless otherwise noted.
This program is funded by California utility customers and administered by Pacific Gas and Electric Company (PG&E), San Diego Gas & Electric Company (SDG&E®), and Southern California Edison Company (SCE) under the auspices of the California Public Utilities Commission.

© 2026 PG&E, SDG&E and SCE. All rights reserved, except that this content may be used, copied, and distributed without modification. Neither PG&E, SDG&E, nor SCE — nor any of their employees makes any warranty, express of implied; or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any data, information, method, product, policy or process disclosed in this document; or represents that its use will not infringe any privately-owned rights including, but not limited to patents, trademarks or copyrights.