| Single‐phase | Three‐phase | ||
| kVA | Impedance (%) | kVA | Impedance (%) | 
| 10 | 1.0–4.5 | 15 | 1.0–4.5 | 
| 15 | 1.0–4.5 | 30 | 1.0–4.5 | 
| 25 | 1.0–4.5 | 45 | 1.0–4.5 | 
| 37.5 | 1.0–4.5 | 75 | 1.0–5.0 | 
| 50 | 1.5–4.5 | 112.5 | 1.2–6.0 | 
| 75 | 1.5–4.5 | 150 | 1.2–6.0 | 
| 100 | 1.5–4.5 | 225 | 1.2–6.0 | 
| 167 | 1.5–4.5 | 300 | 1.2–6.0 | 
| 250 | 1.5–6.0 | 500 | 1.5–7.0 | 
| 333 | 1.5–6.0 | 750 | 5.0–7.5 | 
| 500 | 1.5–7.0 | 1000 | 5.0–7.5 | 
| 667 | 5.0–7.5 | 1500 | 5.0–7.5 | 
| 833 | 5.0–7.5 | 2000 | 5.0–7.5 | 
| 
 | 
 | 2500 | 5.0–7.5 | 
| Single‐phase | Three‐phase | ||
| kVA | Impedance (%) | kVA | Impedance (%) | 
| 15 | 1.5–6.0 | 15 | 1.5–6.0 | 
| 25 | 1.5–6.0 | 30 | 1.5–6.0 | 
| 37.5 | 1.5–6.0 | 45 | 1.5–6.0 | 
| 50 | 1.5–6.0 | 75 | 1.5–6.0 | 
| 75 | 2.0–7.0 | 112.5 | 1.5–6.0 | 
| 100 | 2.0–7.0 | 150 | 1.5–6.0 | 
| 167 | 2.5–8.0 | 225 | 3.0–7.0 | 
| 250 | 3.5–8.0 | 300 | 3.0–7.0 | 
| 333 | 3.5–8.0 | 500 | 4.5–8.0 | 
| 500 | 3.5–8.0 | 750 | 5.0–8.0 | 
| 667 | 5.0–8.0 | 1000 | 5.0–8.0 | 
| 833 | 5.0–8.0 | 1500 | 5.0–8.0 | 
| 
 | 
 | 2000 | 5.0–8.0 | 
| 
 | 
 | 2500 | 5.0–8.0 | 
| 
 | Appliance | Test Method | 
 | |
| Refrigerated bottled or canned beverage vending machines | ||||
| Refrigerated buffet and preparation tables | ||||
| Other commercial refrigerators, refrigrator-freezers and freezers, with doors | ||||
| Other commercial refrigerators, refrigrator-freezers and freezers, without doors , | ||||
| Walk-in coolers and walk-in freezers | ||||
| Product Class | Maximum Energy Use (kWh/year)* Equation | 
| 1. Refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost | 7.99AV + 225.0 0.28av+ 225.0 | 
| 1A. All-refrigerators -- manual defrost | 6.79AV + 193.6 0.24av + 193.6 | 
| 2. Refrigerator-freezers—partial automatic defrost | 7.99AV + 225.0 0.28av+ 225.0 | 
| 3. Refrigerator-freezers—automatic defrost with top-mounted freezer without an automatic icemaker | 8.07AV + 233.7 0.285av + 233.7 | 
| 3-Bl. Built-in refrigerator-freezer---automatic defrost with top-mounted freezer without an automatic ice maker | 9.15AV + 264.9 0.323av + 264.9 | 
| 3l. Refrigerator-freezer---automatic defrost with top-mounted freezer with an automatic ice maker without through-the-door ice service | 8.07AV + 317.7 0.285av + 317.7 | 
| 3l-Bl Built-in refrigerator-freezers--automatic defrost with top-mounted freezer with an automatic ice maker without through-the-door ice service | 9.15AV + 348.9 0.323av + 348.9 | 
| 3A. All refrigerators—automatic defrost | 7.07AV + 201.6 0.25av + 201.6.0 | 
| 3A-Bl. Built-in All refrigerators—automatic defrost | 8.02AV + 228.5 0.283av + 228.5 | 
| 4. Refrigerator-freezer--automatic defrost with side-mounted freezer without an automatic ice maker | 8.51AV + 297.8 0.301av + 297.8 | 
| 4-Bl. Built-in refrigerator-freezers automatic defrost with side-mounted freezer without an automatic ice maker | 10.22AV + 357.4 0.361av + 357.4 | 
| 4l. Refrigerator-freezer automatic defrost with side-mounted freezer with an automatic ice maker without through-the-door ice service | 8.51AV + 381.8 0301 + 381.8 | 
| 4l-Bl. Built-in refrigerator-freezers automatic defrost with side-mounted freezer with an automatic ice maker without through-the-door ice service | 10.22AV + 441.4 0.361 + 441.4 | 
| 5. Refrigerator-freezer automatic defrost with bottom-mounted freezer without an automatic icemaker | 8.85AV + 317.0 0.312av + 317.0 | 
| 5-Bl. Built-in refrigerator-freezers automatic defrost with bottom-mounted freezer without an automatic icemaker | 9.40AV + 336.9 0.332av + 336.9 | 
| 5l. Refrigerator-freezer automatic defrost with bottom-mounted freezer without an automatic icemaker without through-the-door ice service. | 8.85AV + 401.0 0.312av + 401.0 | 
| 5l-Bl. Built-in refrigerator-freezers automatic defrost with bottom-mounted freezer without an automatic icemaker without through-the-door ice service. | 9.40AV + 420.9 0.332av + 420.9 | 
| 5A. Refrigerator-freezer automatic defrost with bottom-mounted freezer with through-the-door ice service. | 9.25AV + 475.4 0.327av + 475.4 | 
| 5A-Bl. Built-in refrigerator-freezersautomatic defrost with bottom-mounted freezer with through-the-door ice service. | 9.83AV + 499.9 0.347av + 499.9 | 
| 6. Refrigerator-freezer automatic defrost with top-mounted freezer with through-the-door ice service. | 8.40AV + 385.4 0.297av + 385.4 | 
| 7. Refrigerator-freezer automatic defrost with side-mounted freezer with through-the-door ice service. | 8.54AV + 432.8 0.302av + 432.8 | 
| 7-Bl. Built-in refrigerator-freezers automatic defrost with side-mounted freezer with through-the-door ice service. | 10.25AV + 502.6 0.362av + 502.6 | 
| 8. Upright freezers with manual defrost | 5.57AV + 193.7 0.197av + 193.7 | 
| 9. Upright freezers with automatic defrost without an automatic icemaker | 8.62AV + 228.3 0.305av + 228.3 | 
| 9l. Upright freezers with automatic defrost with an automatic icemaker | 8.62AV + 312.3 0.348av + 312.3 | 
| 9-Bl. Built-in upright freezers with automatic defrost without an automatic icemaker | 9.86AV + 260.9 0.348av + 260.9 | 
| 9l-Bl. Built-in upright freezers with automatic defrost with an automatic icemaker | 9.86AV + 344.9 0.348av + 344.9 | 
| 10. Chest freezers and all other freezers except compact freezers | 7.29AV + 107.8 0.257av + 107.8 | 
| 10A. Chest freezers with automatic defrost | 10.24AV + 148.1 0.362av + 148.1 | 
| 11. Compact refrigerator-freezers and refrigerators other than all-refrigerators with manual defrost | 9.03AV + 252.3 0.319av + 252.3 | 
| 11A. Compact all refrigerators---manual defrost | 7.84AV + 219.1 0.277av + 219.1 | 
| 12. Compact refrigerator-freezers--partial automatic defrost | 5.91AV + 335.8 0.209 + 335.8 | 
| 13. Compact refrigerator-freezers--automatic defrost with top-mounted freezer | 11.80AV + 339.2 0.417av + 339.2 | 
| 13l. Compact refrigerator-freezers--automatic defrost with top-mounted freezer with an automatic icemaker | 11.80AV + 423.2 0.417av + 423.2.2 | 
| 13A. Compact all refrigerators---automatic defrost | 9.17AV + 259.3 0.324av + 259.3 | 
| 14. Compact refrigerator-freezers--automatic defrost with side-mounted freezer | 6.82AV + 456.9 0.241av + 456.9 | 
| 14l. Compact refrigerator-freezers--automatic defrost with side-mounted freezer with an automatic icemaker | 6.82AV + 540.9 0.241av + 540.9 | 
| 15. Compact refrigerator-freezers--automatic defrost with bottom-mounted freezer | 11.80AV + 339.2 0.417av + 339.2 | 
| 15l. Compact refrigerator-freezers--automatic defrost with bottom-mounted freezer with an automatic icemaker | 11.80AV + 423.2 0.417av + 423.2 | 
| 16. Compact upright freezers with manual defrost | 8.65AV + 225.7 0.306av + 225.7 | 
| 17. Compact upright freezers with automatic defrost | 10.17AV + 351.9 0.359av + 351.9 | 
| 18. Compact chest freezers | 9.25AV + 136.8 0.327av + 136.8 | 
| *AV = Adjusted total Volume, Expressed in ft3, as determined in 10 C.F.R. sections 430.23(a) (Appendix A to subpart B of part 430) and 430.23(b) (Appendix B to subpart B of part 430) *av = Adjusted total volume, expressed in Liters. | |
| Appliance | Test Method | 
| Room air conditioners and room air‐conditioning heat pumps | 10 C.F.R. section 430.23(f) (Appendix F to Subpart B of part 430) | 
| Pckaged terminal air conditioners and packaged terminal heat pumps | 
| Appliance | Test Method | 
| ‘Computer Room Air Conditioners | |
| evaporatively‐cooled | ANSI/ASHRAE 127‐2001 | 
| air‐cooled, glycol‐cooled, water‐cooled | |
| Other electric‐powered unitary air‐conditioners and electric powered heat pumps | |
| ‘Air‐cooled air conditioners and ‘air‐source heat pumps | |
| < 65,000 Btu/hr, single‐phase | 10 C.F.R. section 430.23(m) (Appendix M to Subpart B of part 430) | 
| < 65,000 Btu/hr, three‐phase | |
| ≥ 65,000 and < 760,000 Btu/hr | |
| ‘evaporatively‐cooled air conditioners < 240,000 Btu/h | |
| ‘water‐cooled air conditioners and water‐source heat pumps<240,000 Btu/hr | |
| ground ’water‐source heat pumps | ARI/ISO‐13256‐1:1998 | 
| ground‐source closed‐loop heat pumps | ARI/ISO‐13256‐1:1998 | 
| Variable Refrigerant Flow Multi‐split Systems | |
| ‘Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps | |
| ’Gas‐fired ‘air conditioners and gas‐fired heat pumps | ANSI Z21.40.4‐1996 as modified by CEC, Efficiency Calculation Method for Gas‐Fired Heat Pumps as a New Compliance Option (1996) | 
| ’Airflow Direction | Thickness (t) of Edges of Blades | Tip ‘Speed Threshhold | ||
| Mn | Inch | m/s | Feet per Minute | |
| Downward Only | 4.8 > t ≥3.2 | 3/16 > t ≥ 1/8 | 16.3 | 3200 | 
| Downward Only | t ≥ 4.8 | t ≥ 3/16 | 20.3 | 4000 | 
| Reversible | 4.8 > t ≥3.2 | 3/16 > t ≥ 1/8 | 12.2 | 2400 | 
| Reversible | t ≥ 4.8 | t ≥ 3/16 | 16.3 | 3200 | 
| Appliance | Test Method | 
| Central furnaces | |
| < 225,000 Btu/hr, single phase | 10 C.F.R. section 430.23(n) (Appendix N to Subpart B of part 430) | 
| 10 C.F.R. section 430.23(n) (Appendix N to Subpart B of part 430) or 10 C.F.R. sections 431.75 and 431.76 (at manufacturer’s option) | |
| ≥ 225,000 Btu/hr | |
| ‘Gas infrared heaters | |
| patio heaters | ASTM F2644‐07 | 
| high‐intensity infrared heaters | ANSI Z83.19‐2001 | 
| low‐intensity infrared heaters | ANSI Z83.20‐2001 | 
| Gas Duct Furnaces | ANSI Z83.8‐2002* | 
| Boilers | |
| < 300,000 Btu/hr | 10 C.F.R. section 430.23(n) (Appendix N to Subpart B of part 430) | 
| ≥ 300,000 Btu/hr | |
| Wall furnaces, floor furnaces, and room heaters | 10 C.F.R. section 430.23(o) (Appendix O to Subpart B of part 430) | 
| ’Water Heater Type | Indicator on non-residential application | 
| ‘Gas-fired Storage | Rated Input > 105 kBtu/hour; rated storage volume > 120 gallons | 
| Oil-fired Storage | Rated ‘Input > 140 kBtu/hour; rated storage volume > 120 gallons> | 
| Electric Instantaneous | Rated ‘Input > rated storage volume > 2 gallons> | 
| Rated Storage Volume and Input Rating (if applicable) | Draw Pattern | Minimum Uniform Energy Factor* | |
| ≥ 20 gallons and ≤ 55 gallons | Very small | 0.3456 – (0.0020 x Vr) | |
| Low | 0.5982 – (0.0019 x Vr) | ||
| Medium | 0.6483 – (0.0017 x Vr) | ||
| High | 0.6920 – (0.0013 x Vr) | ||
| > 55 gallons and ≤ 100 gallons | Very small | 0.6470 – (0.0006 x Vr) | |
| Low | 0.7689 – (0.0005 x Vr) | ||
| Medium | 0.7897 – (0.0004 x Vr) | ||
| High | 0.8072 – (0.0003 x Vr) | ||
| Oil-Fired Storage Water Heater | ≤ 50 gallons | Very small | 0.2509 – (0.0012 x Vr) | 
| Low | 0.5330 – (0.0016 x Vr) | ||
| Medium | 0.6078 – (0.0016 x Vr) | ||
| High | 0.6815 – (0.0014 x Vr) | ||
| Electric Storage Water Heater | ≥ 20 gallons and ≤ 55 gallons | Very small | 0.8808 – (0.0008 x Vr) | 
| Low | 0.9254 – (0.0003 x Vr) | ||
| Medium | 0.9307 – (0.0002 x Vr) | ||
| High | 0.9349 – (0.0001 x Vr) | ||
| > 55 gallons and ≤ 120 gallons | Very small | 1.9236 – (0.0011 x Vr) | |
| Low | 2.0440 – (0.0011 x Vr) | ||
| Medium | 2.1171 – (0.0011 x Vr) | ||
| High | 2.2418 – (0.0011 x Vr) | ||
| Tabletop Water Heater | ≥ 20 gallons and ≤ 120 gallons | Very small | 0.6323 – (0.0058 x Vr) | 
| Low | 0.9188 – (0.0031 x Vr) | ||
| Medium | 0.9577 – (0.0023 x Vr) | ||
| High | 0.9884 – (0.0016 x Vr) | ||
| Instantaneous Gas-fired Storage Water Heater | < 2 gallons and > 50,000 Btuh | Very small | 0.80 | 
| Low | 0.81 | ||
| Medium | 0.81 | ||
| High | 0.81 | ||
| Instantaneous Electric Water Heater | < 2 gallons | Very small | 0.91 | 
| Low | 0.91 | ||
| Medium | 0.91 | ||
| High | 0.92 | ||
| Grid-Enabled Water Heater | > 75 gallons | Very small | 1.0136 – (0.0028 x Vr) | 
| Low | 0.9984 – (0.0014 x Vr) | ||
| Medium | 0.9853 – (0.0010 x Vr) | ||
| High | 0.9720 – (0.0007 x Vr) | ||
| *Vr = Rated Storage Volume in gallons | |||
| Appliance | Effective Date | Minimum Thermal ‘Efficiency (%) | 
| ‘Gas-Fired ‘Pool Heaters | April 16, 2013 | 82 | 
| -Oil-Fired Pool Heaters | January 1, 1990 | 78 | 
| Appliance | Test Method | 
| Cooking products that are consumer products | 10 C.F.R. section 430.23(i) (Appendix I to Subpart B of part 430) | 
| Combined cooking products | 10 C.F.R. section 430.23(i) (Appendix I to Subpart B of part 430) | 
| Commercial hot food holding cabinets | ANSI/ASTM F2140-01 (Test for idle energy rate-dry test) and US EPA’s Energy Star Guidelines, “Measuring Interior Volume” (Test for interior volume) | 
| Commercial convection ovens | ANSI/ASTM F1496-99 (Test for energy input rate and idle energy consumption only) | 
| Commercial range tops | ANSI/ASTM F1521-96 (Test for cooking energy efficiency only) | 
| Product Class | Minimum Annual Energy Use (AEU) (kWh/Year) | 
| Coolers | |
| Built-in Compact Cooler | 7.88Av + 155.8 | 
| Built-in Cooler | |
| Freestanding Compact Cooler | |
| Freestanding Cooler | |
| Combination Coolers | |
| Combination Cooler with all refrigerator-automatic defrost | 4.57AV + 130.4 | 
| Built-in combination cooler with all refrigerator-automatic defrost | 5.19AV + 147.8 | 
| Combination Cooler with upright freezers with automatic defrost without an automatic ice maker | 5.58AV + 147.7 | 
| Built-in combination cooler with upright freezers with automatic defrost without an automatic ice maker | 6.38AV + 168.8 | 
| Combination Cooler with upright freezer with automatic defrost with an automatic ice maker | 5.58AV + 231.7 | 
| Built-in combination cooler with upright freezer with automatic defrost with an automatic ice maker | 6.38AV + 252.8 | 
| Compact combination cooler with all refrigerator-automatic defrost | 5.93AV + 193.7 | 
| Built-in compct combination cooler with all refrigerator-automatic defrost | 6.52AV + 213.1 | 
| AV= Adjusted total volume, expressed in ft3, as calculated according to 10 C. F. R. Appendix A to subpart B of part 430. | |
Table A-4
Standards for 
Commercial Refrigerators, Refrigerator-Freezers 
with a Self-Contained 
Condensing Unit That are Not Commercial Hybrid Units
| Equipment Category and Effective Date | Condensing Unit Configuration | Equipment Family | Rating 
      Temperature | Operating 
      Temperature | Equipment Class Designation* | Maximum Daily Energy Consumption (kWh) | 
| Refrigerators and Freezers | Self Contained (SC) | Vertical Closed Transparent (VCT) | 38 (M) | ≥ 32 | VCT, SC, M | 0.1 × V + 0.86 | 
| Vertical Closed Solid (VCS) | 38 (M) | ≥ 32 | VCS, SC, M | 0.05 × V + 1.36 | ||
| Horizontal Closed Transparent (HCT) | 38 (M) | ≥ 32 | HCT, SC, M | 0.06 × V + 0.37 | ||
| Horizontal Closed Solid (HCS) | 38 (M) | ≥ 32 | HCS, SC, M | 0.05 × V + 0.91 | ||
| Service Over Counter (SOC) | 38 (M) | ≥ 32 | SOC, SC, M | 0.51 x TDA + 1.0 | ||
| Refrigerators with transparent doors | Self Contained (SC) | Pull Down PD) | 38 (P) | ≥ 32 | PD, SC, M | 0.11 × V + 0.81 | 
| Refrigerators and Freezers without Doors | Self Contained (SC) | Vertical Open (VOP) | 38 (M) | ≥ 32 | VOP, SC, M | 1.69 × TDA + 4.71 | 
| Semivertical Open (SVO) | 38 (M) | ≥ 32 | SVO, SC, M | 1.70 × TDA + 4.59 | ||
| Horizontal Open (HZO) | 38 (M) | ≥ 32 | HZO, SC, M | 0.72 × TDA + 5.55 | ||
| * The meaning of the letters in this column is indicated in the Condensing Unit Configuration, Equipment Family, and Rating Temperature (°F) columns to the left. | ||||||
| Equipment Category | Condensing Unit Configuration | Equipment Family | Rating Temperature (°F) | Operating Temperature (°F) | Equipment Class Designation* | Maximum Daily Energy Consumption (kWh) | 
| Refrigerators and Freezers | ‘Remote (RC) | Vertical Open (VOP) | 38 (M) | ≥ 32 | VOP, RC, M | 0.64 × TDA + 
      4.07 | 
| Semivertical Open (SVO) | 38 (M) | ≥ 32 | SVO, RC, M SVO, RC, L | 0..66 × TDA + 
      3.18 | ||
| Horizontal Open (HZO) | 38 (M) | ≥ 32 | HZO, RC, M | 0.35 × TDA + 
      2.88 | ||
| Vertical Closed Transparent (VCT) | 38 (M) | ≥ 32 | VCT, RC, M | 0..15 × TDA + 
      1.95 | ||
| Horizontal Closed Transparent (HCT) | 38 (M) | ≥ 32 | HCT, RC, M | 0.16 × TDA + 0.13 | ||
| Vertical Closed Solid (VCS) | 38 (M) | ≥ 32 | VCS, RC, M | 0.10 × V + 
      0.26 | ||
| Horizontal Closed Solid (HCS) | 38 (M) | ≥ 32 | HCS, RC, M | 0.10 × V + 
      0.26 | ||
| Service Over | 38 (M) | ≥ 32 | SOC, RC, M | 0..44 × TDA + 
      0.11 | ||
| * The meaning of the letters in this column is indicated in the Condensing Unit Configuration, Equipment Family, and Rating Temperature (°F) columns to the left. | ||||||
| Equipment type | Type of cooling | Harvest rate | Maximum ‘energy use (kWh/100 lbs ice) | Maximum condenser water use* (gal/100 lbs ice) | 
| Ice Making Head | Water | < 500 | 7.80–0.0055H | 200–0.022H. | 
| ≥ 500 and < 1436 | 5.58–0.0011H | 200–0.022H. | ||
| ≥ 1436 | 4.0 | 200–0.022H. | ||
| Ice Making Head | Air | < 450 | 10.26–0.0086H | Not applicable. | 
| ≥ 450 | 6.89-0.0011H | Not applicable. | ||
| Remote Condensing (but not remote compressor) | Air | < 1000 | 8.85–0.0038H | Not applicable. | 
| ≥ 1000 | 5.1 | Not applicable. | ||
| Remote Condensing and Remote Compressor) | < 934 | 8.85–0.0038H | Not applicable. | |
| ≥ 934 | 5.3 | Not applicable. | ||
| Self Contained | Water | < 200 | 11.40-0.019H | 191–0.0315H. | 
| ≥ 200 | 7.6 | 191–0.0315H. | ||
| Self Contained | Air | < 175 | 18.0–0.0469H | Not applicable. | 
| ≥ 175 | 9.8 | Not applicable. | ||
| H Harvest rate in pounds per 24 hours. *Water use is for the condenser only and does not include potable water used to make ice. | ||||
| Appliance | Louvered Sides | Cooling Capacity (Btu/hr) | Minimum EER | 
| Room ‘Air Conditioner | Yes | < 6,000 | 11.0 | 
| Room Air Conditioner | Yes | ≥ 6,000 – 7,999 | 11.0 | 
| Room Air Conditioner | Yes | ≥ 8,000 – 13,999 | 10.9 | 
| Room Air Conditioner | Yes | ≥ 14,000 – 19,999 | 10.7 | 
| Room Air Conditioner | Yes | ≥ 20,000 – 27,999 | 9.4 | 
| Room Air Conditioner | Yes | ≥ 28,000 | 9.0 | 
| Room Air Conditioner | No | < 6,000 | 10.0 | 
| Room Air Conditioner | No | ≥ 6,000 – 7,999 | 10.0 | 
| Room Air Conditioner | No | ≥ 8,000 – 10,999 | 9.6 | 
| Room Air Conditioner | No | ≥ 11,000 – 13,999 | 9.5 | 
| Room Air Conditioner | No | ≥ 14,000 – 19,999 | 9.3 | 
| Room Air Conditioner | No | ≥20,000 | 9.4 | 
| Room Air Conditioning Heat Pump | Yes | < 20,000 | 9.8 | 
| Room Air Conditioning Heat Pump | Yes | ≥20,000 | 9.3 | 
| Room Air Conditioning Heat Pump | No | < 14,000 | 9.3 | 
| Room Air Conditioning Heat Pump | No | ≥14,000 | 8.7 | 
| Casement‐Only Room Air Conditioner | Either | Any | 9.5 | 
| Casement‐Slider Room Air Conditioner | Either | Any | 10.4 | 
| Appliance | Cooling Capacity | Minimum ‘Efficiency | |
| Minimum EER | Minimum COP | ||
| Packaged terminal air conditioners | < 7,000 | 9.4 | — | 
| > 7,000 and < 15,000 | 10.9 – (0.213 x Cap1) | — | |
| > 15,000 | 7.7 | — | |
| Packaged terminal ‘heat pumps | < 7,000 | 9.3 | 2.7 | 
| > 7,000 and < 15,000 | 10.8 – (0.213 x Cap1) | 2.9 ‐ (0.026 x Cap1) | |
| > 15,000 | 7.6 | 2.5 | |
| 1Cap means cooling capacity in thousand British thermal units per hour (Btu/h) at 95°F outdoor dry-bulb | |||
| Appliance | Test Method | 
| Air Filter Pressure Drop | |
| Minimum ’Efficiency Reporting Value (MERV) | ASHRAE 52.2-2012 | 
| Air Filter Particle Size Efficiency | AHRI 680-2009 or ASHRAE 52.2-2012 | 
| Dust Holding Capacity | AHRI 680-2009 or ASHRAE 52.2-2012 | 
| *MERV not reportable for models being tested to AHRI 680-2009 only. | |
| Appliance | Minimum SEER | Minimum HSPF | Minimum EER | Average Off‐ Mode Power Consumption Pw. pff (watts) | 
| Split system ‘air conditioners with rated cooling capacity < 45,000 Btu/hour¹ | 14.0 | — | 12.2 | 30 | 
| Split system air conditioners with rated cooling capacity ≥ 45,000 Btu/hour¹ | 14.0 | 11.7 | 30 | |
| Split system heat pumps with rated cooling capacity < 45,000 Btu/hour¹ | 14.0 | 8.2 | 
 | 33 | 
| Split system heat pumps with rated cooling capacity ≥ 45,000 Btu/hour¹ | 
 | 33 | ||
| Single package air conditioners1 | 14.0 | 
 | 11.0 | 30 | 
| Single package heat pumps | 14.0 | 8.0 | 
 | 33 | 
| Space constrained air conditioners – split system | 12.0 | 
 | — | 30 | 
| Space constrained heat pumps – split system | 12.0 | 7.4 | — | 33 | 
| Space constrained air conditioners – single package | 12.0 | 
 | — | 30 | 
| Space constrained heat pumps – single package | 12.0 | 7.4 | — | 33 | 
| Small duct, high velocity ‘air conditioner systems | 12.0 | 
 | — | 30 | 
| Small duct, high velocity ‘heat pump systems | 12.0 | 7.2 | — | 30 | 
| 1 See 10 C.F.R. section 430.32(c) for less stringent federal standards applicable to these units that are manufactured on or after JANUARY 1, 2015 and installed in states other than Arizona, California, Nevada, or New Mexico | ||||
| Cooling Capacity | Sub-category | Heating Type* | Efficiency Levels | Compliance date: Equipment Manufactured starting on | |
| Small Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled, 3-Phase, Split System) | < 65,000 Btu/h | AC | ALL | SEER = 13.0 | June 16, 2008 | 
| HP | SEER = 14.0 | January 1, 2017 
 | |||
| Small Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled, 3-Phase, Single Package) | ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | ALL | SEER = 14.0 | January 1, 2017 | 
| HP | SEER = 14.0 | January 1, 2017 | |||
| Small Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 65,000 Btu/h and < 135,000 Btu/h | AC | E-N | EER = 11.2 | January 1, 20101 | 
| IEER = 12.9 | January 1, 20182 | ||||
| IEER = 14.8 | January 1, 2023 | ||||
| A-O | EER = 11.0 | January 1, 20101 | |||
| IEER = 12.7 | January 1, 20182 | ||||
| IEER = 14.6 | January 1, 2023 | ||||
| HP | E-N | EER = 11.0 | January 1, 20101 | ||
| IEER = 12.2 | January 1, 20182 | ||||
| IEER = 14.1. | January 1, 2023 | ||||
| A-O | EER = 10.8 | January 1, 20101 | |||
| IEER = 12.0 | January 1, 20182 | ||||
| IEER = 13.9. | January 1, 2023 | ||||
| Large Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | E-N | EER = 11.0 | January 1, 20101 | 
| IEER = 12.4 | January 1, 20182 | ||||
| IEER = 14.2 | January 1, 2023 | ||||
| A-O | EER = 10.8 | January 1, 20101 | |||
| IEER = 12.2 | January 1, 20182 | ||||
| IEER = 14.0 | January 1, 2023 | ||||
| HP | E-N | EER = 10.6 | January 1, 20101 | ||
| IEER = 11.6 | January 1, 20182 | ||||
| IEER = 13.5. | January 1, 2023 | ||||
| A-O | EER = 10.4 | January 1, 20101 | |||
| IEER = 11.4 | January 1, 20182 | ||||
| IEER = 13.3. | January 1, 2023 | ||||
| Very Large Commercial Package Air-Conditioning and Heating Equipment (Air-Cooled) | ≥ 240,000 Btu/h and < 760,000 Btu/h | AC | E-N | EER = 10.0 | January 1, 20101 | 
| IEER = 11.6 | January 1, 20182 | ||||
| IEER = 13.2 | January 1, 2023 | ||||
| A-O | EER = 9.8 | January 1, 20101 | |||
| IEER = 11.4 | January 1, 20182 | ||||
| IEER = 13.0 | January 1, 2023 | ||||
| HP | E-N | EER = 9.5 | January 1, 20101 | ||
| IEER = 10.6 | January 1, 20182 | ||||
| IEER = 12.5 | January 1, 2023 | ||||
| A-O | EER = 9.3 | January 1, 20101 | |||
| IEER = 10.4 | January 1, 20182 | ||||
| IEER = 12.3 | January 1, 2023 | ||||
| 1 And 
      manufactured before January 1, 2018. | |||||
| Cooling Capacity | Sub-category | Heating Type* | Efficiency Levels | Compliance date: Equipment Manufactured starting on | |
| Small Commercial Package Air-Conditioning and Heating Equipment (Water-Cooled) | < 65,000 Btu/h | AC | ALL | EER = 12.1 | October 29, 2003 | 
| N-E | EER = 12.1 | June 1, 2013 | |||
| A-O | EER = 11.9 | ||||
| Large Commercial Package Air-Conditioning and Heating Equipment (Water-Cooled) | ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | N-E | EER = 12.5 | June 1, 2014 | 
| A-O | EER = 12.3 | ||||
| Very Large Commercial Package Air-Conditioning and Heating Equipment (Water-Cooled) | ≥ 240,000 Btu/h and < 760,000 Btu/h | AC | N-E | EER = 12.4 | June 1, 2014 | 
| A-O | EER = 12.2 | ||||
| Small Commercial Package Air-Conditioning and Heating Equipment (Evaporatively-Cooled) | < 65,000 Btu/h | AC | ALL | EER = 12.1 | October 29, 2003 | 
| ≥ 65,000 Btu/h and < 135,000 Btu/h | N-E | EER = 12.1 | June 1, 2013 | ||
| A-O | EER = 11.9 | ||||
| Large Commercial Package Air-Conditioning and Heating Equipment (Evaporatively-Cooled) | ≥ 135,000 Btu/h and < 240,000 Btu/h | AC | N-E | EER = 12.0 | June 1, 2014 | 
| A-O | EER = 11.8 | ||||
| Very Large Commercial Package Air-Conditioning and Heating Equipment (Evaporatively-Cooled) | ≥ 240,000 Btu/h and < 760,000 Btu/h | AC | N-E | EER = 11.9 | June 1, 2014 | 
| A-O | EER = 11.7 | ||||
| Small Commercial Package Air-Conditioning and Heating Equipment (Water-Source: Water-to-Air, Water-Loop) | < 17,000 Btu/h | HP | ALL | IEER = 12.2 | October 9, 2015 | 
| ≥ 17,000 Btu/h and < 135,000 Btu/h | IEER = 13.0 | ||||
| * N-E = No Heating or Electric Resistance 
      Heating   | |||||
| ’Airflow Direction | Thickness (t) of Edges of Blades | Tip ‘Speed Threshhold | ||
| Mn | Inch | m/s | Feet per Minute | |
| 4.8 > t ≥3.2 | 3/16 > t ≥ 1/8 | 12.2 | 2400 | |
| Reversible | t ≥ 4.8 | t ≥ 3/16 | 16.3 | 3200 | 
| Appliance | Design  | Capacity  | Minimum AFUE (%) | 
| Effective On or  | |||
| Wall furnace | Fan | ≤ 42,000 | 75 | 
| Wall furnace | Fan | > 42,000 | 76 | 
| Wall furnace | Gravity | 27,000 | 65 | 
| Wall furnace | Gravity | > 27,000 and ≤ 46,000 | 66 | 
| Wall furnace | Gravity | > 46,000 | 67 | 
| Floor furnace | All | ≤ 37,000 | 57 | 
| Floor furnace | All | > 37,000 | 58 | 
| Room heater | All | ≤ 20,000 | 61 | 
| Room heater | All | > 20,000 and < 27,000 | 66 | 
| Room heater | All | > 27,000 and < 46,000 | 67 | 
| Room heater | All | > 46,000 | 68 | 
| Appliance | Minimum AFUE (%) | Maximum Power Consumption | ||||
| Effective | Effective January 15, 2021 | |||||
| AFUE | Standby | Off Mode | ||||
| Gas steam boilers with single phase electrical supply | 801 | 821 | 8 | 8 | ||
| Gas hot ‘water boilers with single phase electrical supply | 821, 2 | 841, 2 | 9 | 9 | ||
| Oil steam ‘boilers with single phase electrical supply | 82 | 85 | 11 | 11 | ||
| Oil hot water boilers with single phase electrical supply | 842 | 862 | 11 | 11 | ||
| Electric steam residential boilers | NONE | NONE | 8 | 8 | ||
| Electric hot water residential boilers | NONE2 | NONE2 | 8 | 8 | ||
| ¹ No constant 
      burning pilot light design standard effective September 1, 2012. | ||||||
Table E-5
Standards for 
Commercial Gas- and Oil-Fired Central Furnaces
| Appliance | Rated Input (Btu/hr) | Minimum Thermal Efficiency | |
| January 1, 1994 | January 1, 2023 | ||
| Gas central furnaces | ≥ 225,000 | 80 | 81 | 
| Oil central furnaces | ≥ 225,000 | 81 | 82 | 
| Product Class | Rated Storage Volume and Input Rating (if applicable) | Draw Pattern | Minimum Uniform Energy Factor* | 
| Gas-Fired Storage Water Heater | ≥ 20 gallons and ≤ 55 gallons | Very small | 0.3456 – (0.0020 x Vr) | 
| Low | 0.5982 – (0.0019 x Vr) | ||
| Medium | 0.6483 – (0.0017 x Vr) | ||
| High | 0.6920 – (0.0013 x Vr) | ||
| > 55 gallons and ≤ 100 gallons | Very small | 0.6470 – (0.0006 x Vr) | |
| Low | 0.7689 – (0.0005 x Vr) | ||
| Medium | 0.7897 – (0.0004 x Vr) | ||
| High | 0.8072 – (0.0003 x Vr) | ||
| Oil-Fired Storage Water Heater | ≤ 50 gallons | Very small | 0.2509 – (0.0012 x Vr) | 
| Low | 0.5330 – (0.0016 x Vr) | ||
| Medium | 0.6078 – (0.0016 x Vr) | ||
| High | 0.6815 – (0.0014 x Vr) | ||
| Electric Storage Water Heater | ≥ 20 gallons and ≤ 55 gallons | Very small | 0.8808 – (0.0008 x Vr) | 
| Low | 0.9254 – (0.0003 x Vr) | ||
| Medium | 0.9307 – (0.0002 x Vr) | ||
| High | 0.9349 – (0.0001 x Vr) | ||
| > 55 gallons and ≤ 120 gallons | Very small | 1.9236 – (0.0011 x Vr) | |
| Low | 2.0440 – (0.0011 x Vr) | ||
| Medium | 2.1171 – (0.0011 x Vr) | ||
| High | 2.2418 – (0.0011 x Vr) | ||
| Tabletop Water Heater | ≥ 20 gallons and ≤ 120 gallons | Very small | 0.6323 – (0.0058 x Vr) | 
| Low | 0.9188 – (0.0031 x Vr) | ||
| Medium | 0.9577 – (0.0023 x Vr) | ||
| High | 0.9884 – (0.0016 x Vr) | ||
| Instantaneous Gas-fired Storage Water Heater | < 2 gallons and > 50,000 Btuh | Very small | 0.80 | 
| Low | 0.81 | ||
| Medium | 0.81 | ||
| High | 0.81 | ||
| Instantaneous Electric Water Heater | < 2 gallons | Very small | 0.91 | 
| Low | 0.91 | ||
| Medium | 0.91 | ||
| High | 0.92 | ||
| Grid-Enabled Water Heater | > 75 gallons | Very small | 1.0136 – (0.0028 x Vr) | 
| Low | 0.9984 – (0.0014 x Vr) | ||
| Medium | 0.9853 – (0.0010 x Vr) | ||
| High | 0.9720 – (0.0007 x Vr) | ||
| *Vr = Rated Storage Volume in gallons | |||
| Product Class | Minimum Energy Factor* | 
| 0.62 – (0.0019 x Vr) | |
| Oil Water Heater1 | 0.59 – (0.0019 x Vr) | 
| Electric Water Heater1 | 0.95 – (0.00132 x Vr) | 
| *Vr = Rated Storage Volume in gallons 1Applies to water heaters not covered under 10 C. F.R. section 430.32, including but not limited to storage water heaters >1 gal and < 20 gal (mini-tank water heaters) and booster water heaters. These standards will take effect on the effective date of a federal test procedure that converts Uniform Energy Factor (UEF) to Energy Factor for these products. If the Secretary adopts federal efficiency standards for water heaters regulated under 42 U. S. C. section 6295(e)(1), these standards shall not apply | |
 Table H-1
Table H-1| Appliance | Maximum Flow Rate | 
| Wash fountains | 2.2xrim space (inches)/20 gpm at 60psi | 
| Metering ‘faucets | 0.25 gallons/cycle 1, 2 | 
| Metering faucets for wash fountains | 0.25xrim space (inches)/20 gpm at 60 psi 1, 2 | 
| 1Sprayheads with independently‐controlled orifices and metered controls. The maximum flow rate of each orifice that delivers a pre‐set volume of water before gradually shutting itself off shall not exceed the maximum flow rate for a metering faucet. 2Sprayheads with collectively‐controlled orifices and metered controls. The maximum flow rate of a sprayhead that delivers a pre‐set volume of water before gradually shutting itself off shall be the product of (a) the maximum flow rate for a metering ‘faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)). | |
| Time Variable | Measurements Taken | |||
| P80,P50 | P80,NoP50 | NoP80,P50 | NoP80, NoP50 | |
| W100 | 0.2 | 0.35 | 0.45 | 1 | 
| W80 | 0.5 | 0.65 | 0 | 0 | 
| W50 | 0.3 | 0 | 0.55 | 0 | 
| BLE = A/(1 + b*average total lamp arc power ᴧ -C) Where A, B, and C are as follows: | |||
| Description | A | B | C | 
| Instant start and rapid start ballasts (not classified as residential) that are designed to operate | 0.993 | 0.27 | 0.25 | 
| 4‐foot medium bi‐pin lamps | 
 | 
 | 
 | 
| 2‐foot U‐shaped lamps | 
 | 
 | 
 | 
| 8-foot slimline lamps | 
 | 
 | 
 | 
| Programmed start ballasts (not classified as residential) that are designed to operate | 0.993 | 0.51 | 0.37 | 
| 4‐foot medium bi‐pin lamps | 
 | 
 | 
 | 
| 2‐foot U‐shaped lamps | 
 | 
 | 
 | 
| 4‐foot minature bi‐pin standard output lamps | 
 | 
 | 
 | 
| 4‐foot miniature bi‐pin high output lamps | 
 | 
 | 
 | 
| Instant start and rapid start ballasts (not classified as sign ballasts) that are designed to operate 8-foot high output lamps | 0.993 | 0.38 | 0.25 | 
| Programmed start ballasts (not classified as sign ballasts) that are designed to operate 8-foot high output lamps | 0.973 | 0.70 | 0.37 | 
| Sign ballasts that operate 8-foot high output lamps | 0.993 | 0.47 | 0.25 | 
| Instant start and rapid start residential ballasts that operate | 0.993 | 0.41 | 0.25 | 
| 4‐foot medium bi‐pin lamps | 
 | 
 | 
 | 
| 2‐foot U‐shaped lamps | 
 | 
 | 
 | 
| 8-foot slimline lamps | 
 | 
 | 
 | 
| Programmed start residential ballasts that are designed to operate | 0.973 | 0.71 | 0.37 | 
| 4‐foot medium bi‐pin lamps | 
 | 
 | 
 | 
| 2‐foot U‐shaped lamps | 
 | 
 | 
 | 
| Measurement | Test Procedure | Required or Optional | 
| Flicker | Title 24, part 6, Joint Appendix 10 (2015), tested at both 100 percent and 20 percent output. Lamps with a percent amplitude modulation (percent flicker) less than 30 percent at frequencies less than 200Hz shall report “yes” for “reduced flicker operation” described in section 1606|tag=1606_a_Filing_of_Statements_ of this Article, otherwise report “no.” | Optional | 
| Lumen Maintenance, Rated Life, and Survival Rate for Compliance with Title 24 Joint Appendix 8 and minimum dimming level | Title 24, part 6, Joint Appendix 8 (2015) | Optional | 
| Audible Noise | ENERGY STAR Recommended Practice—Noise (2013) with the following modification: measurements shall be taken at 100 percent output as we as at 20 percent output if dimmable. | Optional | 
| Appliance | Correlated Color Temperature | Minimum Average Lamp Efficacy (LPW) | |
| Effective | Effective | ||
| 4‐foot medium bi‐pin lamps | ≤ 4,500K | 89 | 92.4 | 
| > 4,500K and ≤ 7,000K | 88 | 88.7 | |
| 2‐foot U‐shaped lamps | ≤ 4,500K | 84 | 85.0 | 
| > 4,500K and ≤ 7,000K | 81 | 83.3 | |
| ≤ 4,500K | 97 | 97.0 | |
| > 4,500K and ≤ 7,000K | 93 | 93.0 | |
| 8‐foot high output lamps | ≤ 4,500K | 92 | 92.0 | 
| > 4,500K and ≤ 7,000K | 88 | 88.0 | |
| 4-foot miniature bipin standard output | ≤ 4,500K | 86 | 95.0 | 
| > 4,500K and ≤ 7,000K | 81 | 89.3 | |
| 4-foot miniature bipin high output | ≤ 4,500K | 76 | 82.7 | 
| > 4,500K and ≤ 7,000K | 72 | 76.9 | |
| ‘Lamp Spectrum | Lamp Diameter (inches) | Rated Voltage | Minimum Average ‘Lamp Efficacy (LPW)1 | 
| Standard Spectrum | > 2.5 | ≥ 125 | 6.8 x P0.27 | 
| < 125 | 5.9 x P0.27 | ||
| ≤ 2.5 | ≥ 125 | 5.7 x P0.27 | |
| < 125 | 5.0 x P0.27 | ||
| Modified Spectrum | > 2.5 | ≥ 125 | 5.8 x P0.27 | 
| < 125 | 5.0 x P0.27 | ||
| ≤ 2.5 | ≥ 125 | 4.9 x P0.27 | |
| < 125 | 4.2 x P0.27 | ||
| 1P = Rated Lamp Wattage, in Watts | |||
| Factor | Requirements | 
| ‘Labeled Wattage (Watts) and Configuration¹ | Measured Initial Lamp Efficacy: lumens/watt must be at least² | 
| Bare Lamp: | 
 | 
| Covered Lamp (no reflector) | 
 | 
| Lumen Maintenance at 1,000‐hours | ≥90% | 
| Lumen Maintenance at 40% of Lifetime2 | 80% | 
| Rapid ‘Cycle Stress Test | Each lamp must be cycled once for every two hours of lifetime2. At least 5 lamps must meet or exceed the minimum number of ‘cycles. | 
| Lifetime2 | ≥ 6,000 | 
| ¹ Use labeled 
      wattage to determine the appropriate efficacy requirements in this table; 
      do not use measured wattage for this purpose | |
| Rated Lumen Ranges | Maximum Rate Wattage | Minimum Rate Lifetime | Effective Date | 
| 1490 ‐ 2600 | 72 | 1,000 hours | January 1, 2012 | 
| 1050 – 1489 | 53 | 1,000 hours | January 1, 2013 | 
| 750 – 1049 | 43 | 1,000 hours | January 1, 2014 | 
| 310 – 749 | 29 | 1,000 hours | January 1, 2014 | 
| Rated Lumen Ranges | Maximum Rate Wattage | Minimum Rate Lifetime | Effective Date | 
| 1118 ‐ 1950 | 72 | 1,000 hours | January 1, 2012 | 
| 788 ‐ 1117 | 53 | 1,000 hours | January 1, 2013 | 
| 563 ‐ 787 | 43 | 1,000 hours | January 1, 2014 | 
| 232 ‐ 562 | 29 | 1,000 hours | January 1, 2014 | 
| Lamp Base Type | Maximum Rated Wattage | 
| Candelabra | 60 | 
| Intermediate | 40 | 
| Appliance | Maximum Wattage (at 74°C) | Nominal Wattage (at 25°C) | 
| Traffic Signal Module Type: | ||
| 12‐inch; Red Ball | 17 | 11 | 
| 8‐inch; Red Ball | 13 | 8 | 
| 12‐inch; Red Arrow | 12 | 9 | 
| 12‐inch; Green Ball | 15 | 15 | 
| 8‐inch; Green Ball | 12 | 12 | 
| 12‐inch; Green Arrow | 11 | 11 | 
| Pedestrian Module Type: | ||
| Combination Walking Man/Hand | 16 | 13 | 
| Walking Man | 12 | 9 | 
| Orange Hand | 16 | 13 | 
Table O 
Standards for 
Dishwashers
| Appliance | Effective May 30, 2013 | |
| Maximum ‘Energy Use (kWh/year) | Maximum ‘Water Use (gallons/cycle) | |
| Compact ‘dishwashers | 222 | 3.5 | 
| Standard dishwashers | 307 | 5.0 | 
| Appliance | Minimum Integrated Modified ‘Energy Factor | Maximum Integrated Water Factor | |||||
| March 7, 2015 | January 1, 2018 | March 7, 2015 | January 1, 2018 | ||||
| Top‐loading, Compact | 0.86 | 1.15 | 14.4 | 12.0 | |||
| Top‐loading, Standard | 1.29 | 1.57 | 8.4 | 6.5 | |||
| Front‐loading, Compact | 1.13 | 1.13 | 8.3 | 8.3 | |||
| Front‐loading, Standard | 1.84 | 1.84 | 4.7 | 4.7 | |||
| Appliance | Minimum Modified Energy Factor | Maximum Water Factor | 
| Effective January 8, 2013 | Effective January 8, 2013 | |
| Top-loading clothes washers | 1.60 | 8.5 | 
| Front-loading clothes washers | 2.00 | 5.5 | 
| 
 | Modified Energy Factor (MEF) ft3/kWh/cycle | Integrated Water Factor (IWF) gal./ft3cycle | 
| Effective January 1, 2018 | Effective January 1, 2018 | |
| Top-loading clothes washers | 1.35 | 8.8 | 
| Front-loading clothes washers | 2.00 | 4.1 | 
| Appliance | Minimum Modified Energy Factor | Maximum Water Factor | ||
| Effective January 1, 2007 | Effective | Effective January 1, 2007 | Effective | |
| Top‐loading clothes washers | 1.26 | 1.60 | 9.5 | 8.5 | 
| Front‐loading clothes washers | 1.26 | 2.00 | 9.5 | 5.5 | 
| Appliance | Minimum Combined Energy Factor (lbs/kWh) | |
| Vented | Ventless | |
| Electric, standard clothes dryers | 3.73 | --- | 
| Electric, compact, 120 volt clothes dryers | 3.61 | --- | 
| 3.27 | 2.55 | |
| Electric, combination washer-dryer | --- | 2.08 | 
| Gas clothes dryers | 3.30 | --- | 
| Nominal Full‐Load Efficiency | ||||||||
| 2 pole | 4 pole | 6 pole | 8 pole | |||||
| Enclosed | Open | Enclosed | Open | Enclosed | Open | Enclosed | Open | |
| 1/0.75 | 77.0 | 77.0 | 85.5 | 85.5 | 82.5 | 82.5 | 75.5 | 75.5 | 
| 1.5/1.1 | 84.0 | 84.0 | 86.5 | 86.5 | 87.5 | 86.5 | 78.5 | 77.0 | 
| 2/1.5 | 85.5 | 85.5 | 86.5 | 86.5 | 88.5 | 87.5 | 84.0 | 86.5 | 
| 3/2.2 | 86.5 | 85.5 | 89.5 | 89.5 | 89.5 | 88.5 | 85.5 | 87.5 | 
| 5/3.7 | 88.5 | 86.5 | 89.5 | 89.5 | 89.5 | 89.5 | 86.5 | 88.5 | 
| 7.5/5.5 | 89.5 | 88.5 | 91.7 | 91.0 | 91 | 90.2 | 86.5 | 89.5 | 
| 10/7.5 | 90.2 | 89.5 | 91.7 | 91.7 | 91 | 91.7 | 89.5 | 90.2 | 
| 15/11 | 91.0 | 90.2 | 92.4 | 93.0 | 91.7 | 91.7 | 89.5 | 90.2 | 
| 20/15 | 91.0 | 91.0 | 93.0 | 93.0 | 91.7 | 92.4 | 90.2 | 91.0 | 
| 25/18.5 | 91.7 | 91.7 | 93.6 | 93.6 | 93.0 | 93.0 | 90.2 | 91.0 | 
| 30/22 | 91.7 | 91.7 | 93.6 | 94.1 | 93.0 | 93.6 | 91.7 | 91.7 | 
| 40/30 | 92.4 | 92.4 | 94.1 | 94.1 | 94.1 | 94.1 | 91.7 | 91.7 | 
| 50/37 | 93.0 | 93.0 | 94.5 | 94.5 | 94.1 | 94.1 | 92.4 | 92.4 | 
| 93.6 | 93.6 | 95.0 | 95.0 | 94.5 | 94.5 | 92.4 | 93.0 | |
| 75/55 | 93.6 | 93.6 | 95.4 | 95.0 | 94.5 | 94.5 | 93.6 | 94.1 | 
| 100/75 | 94.1 | 93.6 | 95.4 | 95.4 | 95.0 | 95.0 | 93.6 | 94.1 | 
| 125/90 | 95.0 | 94.1 | 95.4 | 95.4 | 95.0 | 95.0 | 94.1 | 94.1 | 
| 150/110 | 95.0 | 94.1 | 95.8 | 95.8 | 95.8 | 95.4 | 94.1 | 94.1 | 
| 200/150 | 95.4 | 95.0 | 96.2 | 95.8 | 95.8 | 95.4 | 94.5 | 94.1 | 
| 250/186 | 95.8 | 95.0 | 96.2 | 95.8 | 95.8 | 95.8 | 95.0 | 95.0 | 
| 300/224 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 | 
 | 
 | 
| 350/261 | 95.8 | 95.4 | 96.2 | 95.8 | 95.8 | 95.8 | 
 | 
 | 
| 400/298 | 95.8 | 95.8 | 96.2 | 95.8 | 
 | 
 | 
 | 
 | 
| 450/336 | 95.8 | 96.2 | 96.2 | 96.2 | 
 | 
 | 
 | 
 | 
| 500/373 | 95.8 | 96.2 | 96.2 | 96.2 | 
 | 
 | 
 | 
 | 
| Single phase | Three phase | |||
| kVA | ‘Efficiency (%)¹ | kVA | ‘Efficiency (%)¹ | |
| 15 | 97.7 | 15 | 97.89 | |
| 25 | 98.0 | 30 | 98.23 | |
| 37.5 | 98.2 | 45 | 98.40 | |
| 50 | 98.3 | 75 | 98.60 | |
| 75 | 98.5 | 112.5 | 98.74 | |
| 100 | 98.6 | 150 | 98.83 | |
| 167 | 98.7 | 225 | 98.94 | |
| 250 | 98.8 | 300 | 99.02 | |
| 333 | 98.9 | 500 | 99.14 | |
| 
 | 
 | 750 | 99.23 | |
| 
 | 
 | 1000 | 99.28 | |
| ¹ All efficiency values are at 35 percent of nameplate-rated load, determined according to the DOE Test Method for Measuring the Energy Consumption of distribution Transformers under of 10 C.F.R. part 431. | ||||
| Single phase | Three phase | ||
| kVA | ‘Efficiency (%)¹ | kVA | ‘Efficiency (%)¹ | 
| 10 | 98.70 | 15 | 98.65 | 
| 15 | 98.82 | 30 | 98.83 | 
| 25 | 98.95 | 45 | 98.92 | 
| 37.5 | 99.05 | 75 | 99.03 | 
| 50 | 99.11 | 112.5 | 99.11 | 
| 75 | 99.19 | 150 | 99.16 | 
| 100 | 99.25 | 225 | 99.23 | 
| 167 | 99.33 | 300 | 99.27 | 
| 250 | 99.39 | 500 | 99.35 | 
| 333 | 99.43 | 750 | 99.40 | 
| 500 | 99.49 | 1000 | 99.43 | 
| 667 | 99.52 | 1500 | 99.48 | 
| 833 | 99.55 | 2000 | 99.51 | 
| 
 | 
 | 2500 | 99.53 | 
| ¹ All efficiency values are at 50 percent of nameplate-rated load, determined according to the DOE Test Method for Measuring the Energy Consumption of distribution Transformers under Appenndix A to subpart K of 10 C.F.R. part 431. | |||
| Single phase | Three phase | ||||||
| BIL | BIL | ||||||
| kVA | 20‐45 kV efficiency¹ (%) | 46‐95 kV efficiency¹ (%) | ≥ 96 kV efficiency¹ (%) | kVA | 20‐45 kV efficiency¹ (%) | 46‐95 kV efficiency¹ (%) | ≥ 96 kV efficiency¹ (%) | 
| 15 | 98.10 | 97.86 | 
 | 15 | 97.50 | 97.18 | 
 | 
| 25 | 98.33 | 98.12 | 
 | 30 | 97.90 | 97.63 | 
 | 
| 37.5 | 98.49 | 98.30 | 
 | 45 | 98.10 | 97.86 | 
 | 
| 50 | 98.60 | 98.42 | 
 | 75 | 98.33 | 98.13 | 
 | 
| 75 | 98.73 | 98.57 | 98.53 | 112.5 | 98.52 | 98.36 | 
 | 
| 100 | 98.82 | 98.67 | 98.63 | 150 | 98.65 | 98.51 | 
 | 
| 167 | 98.96 | 98.83 | 98.80 | 225 | 98.82 | 98.69 | 98.57 | 
| 250 | 99.07 | 98.95 | 98.91 | 300 | 98.93 | 98.81 | 98.69 | 
| 333 | 99.14 | 99.03 | 98.99 | 500 | 99.09 | 98.99 | 98.89 | 
| 500 | 99.22 | 99.12 | 99.09 | 750 | 99.21 | 99.12 | 99.02 | 
| 667 | 99.27 | 99.18 | 99.15 | 1000 | 99.28 | 99.20 | 99.11 | 
| 833 | 99.31 | 99.23 | 99.20 | 1500 | 99.37 | 99.30 | 99.21 | 
| 
 | 
 | 
 | 
 | 2000 | 99.43 | 99.36 | 99.28 | 
| 
 | 
 | 
 | 
 | 2500 | 99.47 | 99.41 | 99.33 | 
| ¹ All efficiency values are at 50 percent of nameplate-rated load, determined according to the DOE Test Method for Measuring the Energy Consumption of distribution Transformers under Appendix A to subpart K of 10 C.F.R. part 431 | |||||||
| Nameplate ‘Output | Minimum ‘Efficiency in 
      Active Mode  | 
| Less than 1 watt | 0.5 * Nameplate Output | 
| From 1 watt to not more than 51 watts | The sum of 0.09 times the Natural Logarithm of the Nameplate Output amd 0.5 | 
| Greater than 51 watts | 0.85 | 
| Not more than 250 watts | 0.5 | 
| Equipment type | Type of cooling | Harvest rate | Maximum ‘energy use (kWh/100 lbs ice) | Maximum condenser water use* (gal/100 lbs ice) | 
| Ice Making Head | Water | ≥50 and < 801 | 6.48-0.00267H | 180-0.0198H. | 
| ≥ 801 and < 2500 | 4.34 | 180-0.0198H. | ||
| ≥ 2500 and< 4000 | 4.34 | 130.5 | ||
| Air | ≥ 50 and < 310 | 9.19-0.00629H | Not applicable. | |
| ≥310 and < 820 | 8.23-0.0032H | Not applicable. | ||
| ≥820 and < 4000 | 5.61 | Not applicable. | ||
| Remote Condensing (but not remote compressor) | Air | ≥ 50 and < 800 | 9.7-0.0058H | Not applicable. | 
| ≥ 800 and < 4000 | 5.06 | Not applicable. | ||
| Remote Condensing and Remote Compressor | ≥ 50 and < 800 | 9.9-0.0058H | Not applicable. | |
| ≥ 800 and < 4000 | 5.26 | Not applicable. | ||
| Self-Contained | Water | ≥ 50 and < 900 | 7.6-0.00302H | 153-0.0252H. | 
| ≥ 900 and < 2500 | 4.88 | 153-0.0252H. | ||
| ≥ 2500 and < 4000 | 4.88 | 90 | ||
| Air | ≥ 50 and < 200 | 14.22-0.03H | Not applicable. | |
| ≥ 200 and < 700 | 9.47-0.00624H | Not applicable. | ||
| ≥ 700 and < 4000 | 5.1 | Not applicable. | ||
| H Harvest rate in pounds per 24 hours. *Water use is for the condenser only and does not include potable water used to make ice. | ||||
| Class | Maximum Daily Energy Consumption (kWh/day)* | |
| Display Door, Medium Temperature | DD.M | 0.04 X Add + 0.41 | 
| Display Door, Low Temperature | DD.L | 0.15 X Add + 0.29 | 
| *Add represents the surface area of the display door. | ||
| Class Descriptor | Class | Minimum AWEF (Btu/W-h | 
| Dedicated Condensing, Medum Temperature, Indoor System | DC, M, I | 5.61 | 
| Dedicated Condensing, Medum Temperature, Outddor System | DC, M, 0 | 7.60 | 
| Equipment type | Net sensible ‘cooling capacity (Btu/hr) | Minimum SCOP ‘efficiency | Compliance date: | |
| Downflow unit | Upflow unit | |||
| Air‐Cooled | <65,000 | 2.20 | 2.09 | October 29, 2012 | 
| ≥65,000 and <240,000 | 2.10 | 1.99 | October 29, 2013 | |
| ≥240,000 and <760,000 | 1.90 | 1.79 | October 29, 2013 | |
| Water‐Cooled | <65,000 | 2.60 | 2.49 | October 29, 2012 | 
| ≥65,000 and <240,000 | 2.50 | 2.39 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.40 | 2.29 | October 29, 2013 | |
| Water‐Cooled with a Fluid Economizer | <65,000 | 2.55 | 2.44 | October 29, 2012 | 
| ≥65,000 and <240,000 | 2.45 | 2.34 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.35 | 2.24 | October 29, 2013 | |
| Glycol‐Cooled | <65,000 | 2.50 | 2.39 | October 29, 2012 | 
| ≥65,000 and <240,000 | 2.15 | 2.04 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.10 | 1.99 | October 29, 2013 | |
| Glycol‐Cooled with a Fluid Economizer | <65,000 | 2.45 | 2.34 | October 29, 2012 | 
| ≥65,000 and <240,000 | 2.10 | 1.99 | October 29, 2013 | |
| ≥240,000 and <760,000 | 2.05 | 1.94 | October 29, 2013 | |
| Equipment type | Cooling capacity | Heating type1 | ‘Efficiency level | Compliance date: Products manufactured on and after… | 
| VRF Multi-Split ‘Air Conditioners (Air-Cooled) | <65,000 Btu/h | All | 13.0 SEER | June 16, 2008 | 
| ≥65,000 Btu/h and <135,000 Btu/h | N-E | 11.2 EER | January 1, 2010 | |
| A-O | 11.0 EER | January 1, 2010 | ||
| ≥135,000 Btu/h and <240,000 Btu/h | N-E | 11.0 EER | January 1, 2010 | |
| AO | 10.8 EER | January 1, 2010 | ||
| ≥240,000 Btu/h and <760,000 Btu/h | N-E | 10.0 EER | January 1, 2010 | |
| A-O | 9.8 EER | January 1, 2010 | ||
| VRF Multi-Split ‘Heat Pumps (Air-Cooled) | <65,000 Btu/h | All | 13.0 SEER | June 16, 2008 | 
| ≥65,000 Btu/h and <135,000 Btu/h | N-E | 11.0 EER | January 1, 2010 | |
| A-O | 10.8 EER | January 1, 2010 | ||
| ≥135,000 Btu/h and <240,000 Btu/h | N-E | 10.6 EER | January 1, 2010 | |
| A-O | 10.4 EER | January 1, 2010 | ||
| ≥240,000 Btu/h and <760,000 Btu/h | N-E | 9.5 EER | January 1, 2010 | |
| A-O | 9.3 EER | January 1, 2010 | ||
| VRF Multi-Split Heat Pumps (Water Source) | <17,000 Btu/h | Without Heat Recovery | 12.0 EER | October 29, 2012 | 
| With Heat Recovery | 11.8 EER | October 29, 2012 | ||
| ≥17,000 Btu/h and <65,000 Btu/h | All | 12.0 EER | October 29, 2003 | |
| ≥65,000 Btu/h and <135,000 Btu/h | All | 12.0 EER | October 29, 2003 | |
| ≥135,000 Btu/h and <760,000 Btu/h | Without Heat Recovery | 10.0 EER | October 29, 2013 | |
| With Heat Recovery | 9.8 EER | October 29, 2013 | ||
| 1VRF Multi-Split Heat Pumps ( Air-Cooled ) with heat recovery fall under the category of “All Other Types of Heating” unless they also have electric resistance heating, in which case it falls under the category for “No Heating or Electric Resistance Heating.” *N-E = No Heating or Electric resistance 
      heating | ||||
| Appliance | Output (Btu/hr) | Standards | ||
| Minimum AFUE % | Minimum Combustion Efficiency % * | Maximum Standby Loss (watts) | ||
| Gas steam boilers with 3‐ phase electrical supply | < 300,000 | 75 | — | — | 
| All other boilers with 3‐ phase electrical supply | < 300,000 | 80 | — | — | 
| Natural gas, non‐packaged boilers | ≥300,000 | — | 80 | 147 | 
| LPG Non‐packaged boilers | ≥300,000 | — | 80 | 352 | 
| Oil, non‐packaged boilers | ≥ 300,000 | — | 83 | — | 
| *At both maximum and minimum rated capacity, as provided and allowed by the controls. | ||||
| Appliance | Application | Minimum Efficiency % | 
| Central furnaces with 3‐phase electrical supply | Mobile Home | 75 AFUE | 
| All others | 78 AFUE or 80 Thermal Efficiency (at manufacturer’s option) | 
| Appliance | Fuel | Standards | ||
| Minimum Thermal Efficiency %¹ | Maximum Energy Consumption during standby (watts) | |||
| At maximum rated capacity | At minimum rated capacity | |||
| Duct furnaces | Natural gas | 80 | 75 | 10 | 
| Duct furnaces | LPG² | 80 | 75 | 147 | 
| ¹ As provided and allowed by the 
      controls. | ||||
| Equipment Category | Size | Energy Conservation Standardsa | |
| Maximum standby lossc (equipment manufactured on and after October 29, 2003)b | Minimum thermal efficiency (equipment manufactured on and after October 9, 2015)b (%) | ||
| Electric storage water heaters | All | 0.30 + 27/Vm (%/hr) | N/A | 
| Gas-fired storage water heaters | ≤ 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | 
| > 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | |
| Oil-fired storage water heaters | ≤ 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | 
| > 155,000 Btu/hr | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | |
| Gas-fired instantaneous water heaters and hot water supply boilers | < 10 gallons | N/A | 80 | 
| ≥ 10 gallons | Q/800 + 110(Vr) ½ (Btu/hr) | 80 | |
| Oil-fired instantaneous water heaters and hot water supply boilers | < 10 gallons | N/A | 80 | 
| ≥ 10 gallons | Q/800 + 110(Vr) ½ (Btu/hr) | 78 | |
| aVm is the measured storage volume (in 
      gallons), and Vr is the rated volume (in gallons). Q is the 
      nameplate input rate in Btu/hr. | |||
| Product Class (spray force in ounce force (ozf) | Maximum Flow Rate (gpm) | 
| Product Class 1 ( ≤ 5.0 ozf) | 1.00 | 
| Product Class 2( > 5.0 ozf and ≤ 8.0 ozf) | 1.20 | 
| Product Class 3 ( > 8.0 ozf ) | 1.28 | 
| Effective Date | Minimum Compliance Score | Minimum Efficacy Lumens per Watt | 
| January 1, 2018 | 282 | 68 | 
| July 1, 2019 | 297 | 80 | 
| The compliance score shall be calculated as the sum of the efficacy and 2.3 times the CRI of the lamp | ||
| Incandescent wattage equivalence | Minimum Lumen Output | 
| 40W | 310 | 
| 60W | 750 | 
| 75W | 1050 | 
| 100W | 1490 | 
| 150 | 2500 | 
| Lumen Ranges | Minimum Lamp Efficacy | Minimum Rated Lifetime | Effective Date | 
| All | 45 lumens per watt | 1,000 Hours | Jan, 1, 2018 | 
| Rated Lumen Ranges | Maximum Rated Wattage | Minimum Rated Lifetime | Effective Date | 
| 1118-1950 Lumens | 72 watts | 1,000 Hours | Jan 1, 2011 | 
| 788-1117 Lumens | 53 watts | 1,000 Hours | Jan 1, 2012 | 
| 563-787 Lumens | 43 watts | 1,000 Hours | Jan 1, 2013 | 
| 232-562 Lumens | 29 watts | 1,000 Hours | Jan 1, 2013 | 
Table L-1 Ultrasound Maximum Decibel Values
| Mid-frequency of Sound Pressure Third-Octave Band (in kHz) | Maximum db Level within third-Octave Band(in dB reference 20 micropascals) | 
| Less than 20 | 80 | 
| 20 or more to less than 25 | 105 | 
| 25 or more to less than 31.5 | 110 | 
| 31.5 or more | 115 | 
| Type | At 25°C (77°F) | At 74°C (165.2°F) | 
| Hand or ‘Don’t Walk’ sign or countdown. | 10 watts | 12 watts | 
| Walking Person or ‘Walk’ sign | 9 watts | 12 watts | 
| Designed to be operated with ‘lamps of the following rated ‘lamp wattage | Tested input voltage‡‡ | Minimum standard equation‡‡% | 
| ≥ 50W and ≤ 100W | Tested at 480 V | (1/(1+1.24xP^(-0.351)))-0.020†; | 
| ≥ 50W and ≤ 100W | All others | 1/(1+1.24xP^(-0.351)) | 
| > 100W and < 150†;W | Tested at 480 V | (1/(1+1.24xP^(-0.351)))-0.020†; | 
| > 100W and < 150†;W | All others | 1/(1+1.24xP^(-0.351)) | 
| > 500W and ≤ 1000W | Tested at 480 V | For >500W and ≤ 750W: 0.900 | 
| For >750W and ≤ 1000W: 0.000104xP+0.822 | ||
| For >500W and ≤ 1000W: may not utilize a probe-start ballast | ||
| > 500W and ≤ 1000W | All others | For >500W and ≤ 750W: 0.910 | 
| For >750W and ≤ 1000W: 0.000104xP+0.832 | ||
| For >500W and ≤ 1000W: may not utilize a probe-start ballast | ||
| † Includes 150 W fixtures specified in 10 C.F.R. section 
      431.326 paragraph (b)(3), that are 
      fixtures rated only for 150 W lamps; rated for use in wet locations, as 
      specified by the NFPA 70  section 410.4(A); and containing a ballast 
      that is rated to operate at ambient air temperatures above 500 
      C, as specified by UL  | ||
| Lamp Length (inches) | Minimum Ballast Efficacy Factor (BEF) for one lamp | Minimum Ballast Efficacy Factor (BEF) for two lamps | 
| ≤29 | 4.70 | 2.80 | 
| ≥29 and ≤35 | 3.95 | 2.30 | 
| ≥35 and ≤41 | 3.40 | 1.90 | 
| ≥41 and ≤47 | 3.05 | 1.65 | 
| ≥47 | 2.80 | 1.45 | 
| Powern Supply Type | Nameplate ‘Output Power Pout | Minimum Average ‘Efficiency in Active Mode* | Maximum Power in No-Load Mode [W] | 
| Single-Voltage External AC-DC Power Supply, Basic Voltage | Pout ≤ 1 W | ≥ 0.5 x Pout + 0.16 | ≤ 0.100 | 
| 1 W < Pout ≤ 49 W | ≥ 0.071 x In(Pout) - 0.0014 x Pout +0.67 | ≤ 0.100 | |
| 49 W < Pout ≤ 250 W | ≥ 0.880 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Single-Voltage External AC-DC Power Supply, Low-Voltage | Pout ≤ 1 W | ≥ 0.517 x Pout + 0.87 | ≤ 0.100 | 
| 1 W < Pout ≤ 49 W | ≥ 0.0834 x In(Pout) - 0.0014 x Pout +0.609 | ≤ 0.100 | |
| 49 W < Pout ≤ 250 W | ≥ 0.870 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Single-Voltage External AC-AC Power Supply, Basic Voltage | Pout ≤ 1 W | ≥ 0.5 x Pout + 0.16 | ≤ 0.210 | 
| 1 W < Pout ≤ 49 W | ≥ 0.071 x In(Pout) - 0.0014 x Pout +0.67 | ≤ 0.210 | |
| 49 W < Pout ≤ 250 W | ≥ 0.880 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Single-Voltage External AC-AC Power Supply, Low-Voltage | Pout ≤ 1 W | ≥ 0.517 x Pout + 0.87 | ≤ 0.210 | 
| 1 W < Pout ≤ 49 W | ≥ 0.834 x In(Pout) - 0.0014 x Pout +0.609 | ≤ 0.210 | |
| 49 W < Pout ≤ 250 W | ≥ 0.880 | ≤ 0.210 | |
| Pout >250 W | ≥ 0.875 | ≤ 0.500 | |
| Multiple-Voltage External Power Supply | Pout ≤ 1 W | ≥ 0.497 x Pout + 0.067 | ≤ 0.300 | 
| 1 W < Pout ≤ 49 W | ≥ 0.075 x In(Pout) +0.561 | ≤ 0.300 | |
| Pout > 49W | ≥ 0.860 | ≤ 0.300 | |
| *Expressed as a decimal | |||
Table U-3
Standards for All External Power Supplies Manufactured On or 
After February 10, 2016
| Operation EPS Type | Class A EPS | Non-Class A EPS | 
| Direct Operation EPS | Level VI: 10 C.F.R. 430.32 (w)(1)(ii) | Level VI: 10 C.F.R. 430.32 (w)(1)(i) | 
| Indirect Operation EPS | Level VI: 10 C.F.R. 430.32 (w)(1)(i) | No standards | 
| Interface Type | Interface Score | 
| USB 2.0 or less | 5 | 
| USB 3.0 or 3.1 Gen 1 | 10 | 
| USB 3.1 Gen 2 | 15 | 
| USB ports or Thunderbolt 3.0 or greater that can provide 100 or more watts of power | 100 | 
| USB ports or Thunderbolt 3.0 or greater that can provide from 60 or more to less than 100 watts of power | 60 | 
| USB ports or Thunderbolt 3.0 or greater that can provide from 30 or more to less than 60 watts of power | 30 | 
| Thunderbolt 3.0 or greater or USB ports that are not otherwise addressed in Table V-1 and that cannot provide 30 or more watts of power | 20 | 
| Unconnected USB 2.0 motherboard header | 10 per header | 
| Unconnected USB 3.0 or 3.1 Gen 1 motherboard header | 20 per header | 
| PCI slot other than PCIe x 16 (only count mechanical slots) | 25 | 
| PCIe x 16 (only count mechanical slots) | 75 | 
| Thunderbolt 2.0 or less | 20 | 
| M.2 (except key M) | 10 | 
| IDE, SATA, eSATA | 15 | 
| M.2, key M, SATA express, U.2 | 25 | 
| Integrated liquid cooling | 50 | 
| Either: | 100 | 
| Appliance Type | Effective Date | Maximum Power Usage (Watts) | 
| Compact Audio Products | January 1, 2007 | 2 W in Audio standby‐passive mode for those without a permanently 
      illuminated clock display | 
| Digital Versatile Disc Players and Digital Versatile Disc Recorders | January 1, 2006 | 3 W in Video standby‐passive mode | 
| Product Class | Product Class Description | Rated Battery Energy (Ebatt**) | Special Characteristic or battery voltage | Maximym YEC (kWh/yr) (as a function of Ebatt**) | 
| 1 | Low-Energy | ≤ 5 Wh | Inductive Connection* | 3.04 | 
| 2 | Low-Energy | < 100 Wh | < 4 V | 0.1440 * Ebatt + 2.95 | 
| 3 | Low-Energy | < 10 Wh | ≥ 4 V and ≤ 10V | 1.42 kWh/year | 
| ≥ 10 Wh | 0.0255 * Ebatt + 1.16 | |||
| 4 | Low-Energy | 
 | > 10 V | 0.11 * Ebatt + 3.18 | 
| 5 | Medium-Energy | ≥ 100 Wh and | < 20 V | 0.0257 * Ebatt + .0815 | 
| 6 | Medium-Energy | 
 | ≥ 20 V | 0.0778 * Ebatt + 2.4 | 
| 7 | High-Energy | >3,000 Wh | 
 | 0.0502 * Ebatt + 4.53 | 
| *Inductive connection and designed for use in a wet 
      environment (e.g. electric toothbrushes). | ||||
| Performance Parameter | Standard | |
| Charge Return Factor (CRF) | 100 percent, 80 percent Depth of discharge | CRF≤ 1.10 | 
| 40 percent Depth of discharge | CRF ≤ 1.15 | |
| Power Conversion Efficiency | Greater than or equal to: 89 percent | |
| Power Factor | Greater than or equal to: 0.90 | |
| Maintenance Mode Power (Eb = battery capacity of tested battery) | Less than or equal to: 10 + 0.0012Eb W | |
| No Battery Mode Power | Less than or equal to: 10 W | |